With many thanks to Nick Tusa!
Got a panicked email from Nick Tusa in December 2017. Whilst trying to bring his GPT-750 back to life, he discovered that the cooling fan in the PA assembly was frozen. It appeared to be impossible to take apart, so... what to do??
Here's his fix!
-----------------------------------------------------------------------
The GPT-750 fan motor dilemma is solved.
Tried making a homebrewed armature puller (two bolts/nuts, piece of scrap aluminum and a shaft coupler) and gave pulling the whole assembly out as a whole unit a shot…and, it worked! (See pix below..)
The front bearing was shot and lumpy..the back one okay. Of course, they are two different sized bearings. But found both on Ebay, which saved me a trip across Lake Ponchartrain and a visit to New Orleans to find said bearings.
The front end of the assembly is held in place by a circlip. So, out it came as we tightened up the two puller screws. Then used a small gear puller to remove the bearings from the armature shaft. So, folks, file that one away in TMC restoration hints and kinks.
Boatanchor People will stop at nothing to preserve Radio History!
-----------------------------------------------------
As a further note, I did some investigation into this fan assembly, while Nick was figuring out how to get the motor apart. The motor is TMC MO-107 CCW, and you can find the drawing at:
../../tmc_drawings/drawings_db/mo/mo-107.pdf
This motor turns out to be the same size and shape, and has the same mounting arrangement and shaft size as a modern-day standard HVAC motor. A Dayton model 4M092 appears to be a near-perfect replacement. It's a 1/65th HP motor that operates directly off 120VAC (no capacitor required), 3000 RPM, CCW rotation, with 1/4" flatted shaft. You'd have to cut the shaft to the correct length, and remove the mounting studs at the rear end of the motor, but other than that, this would be an easy replacement!